RG6/U 95% Indoor PVC Jacket CCTV COAXIAL CABLE
Construction Parameters: |
Inner Conductor |
1.02mm/0.04"/18AWG Copper |
Dielectric |
4.45mm/0.175" Foamed PE |
Shield 1 |
Bonded Aluminum Foil Shield |
Shield 2 |
CCA braid wire 95% coverage Diameter Over Shielding: 5.1 mm/0.20" |
Jacket |
6.65±0.15mm /0.262±0.006" PVC Flame Retardation: IEC 60332-1 |
Application |
For Use in Longer CCTV Run Lengths |
Limited Length |
Typical run length up to 1500 feet |
|
Electrical Characteristics: |
Inner Conductor Resistance |
The Max. at 20ºC shall be < 21.2 Ω/km (6.96 Ω/kft) |
Capacitance |
52 ±3 pF/m |
17±0.3 pF/ft |
Impedance |
75 ± 3 Ω |
Return loss |
between 5 and 1000MHz: > 22dB |
Velocity of Propagation |
0.85 |
Sparker Test (VAC) |
4 |
|
Attenuation(20ºC): |
Frequency (MHZ) |
Max Attenuation (dB/100FT) |
Max Attenuation (dB/100m) |
5 |
0.62 |
1.90 |
55 |
1.72 |
5.25 |
187 |
3.07 |
9.35 |
211 |
3.28 |
10.00 |
400 |
4.46 |
13.61 |
500 |
5.01 |
15.29 |
750 |
6.08 |
18.54 |
860 |
6.56 |
20.01 |
1000 |
7.05 |
21.49 |
|
Mechanical and Envrionmental Properties |
Cable bend radius |
10 times the cable diameter |
Operating Temp Range (PVC) |
-20 ºC to 60ºC |
Cable diamensions |
6.96±0.15 mm PVC |
|
Order Informations: |
Marking |
RG6/U BC Bonded 95% BC ×××M |
Package |
500FT/Pull Box, 1000FT/Wooden Spool, Pallet |
Delivery time |
Normally 25 days after received the deposit. |